Cisco ASR 907 Installing page 14

Hide thumbs Also See for ASR 907:
Table of Contents

Advertisement

Installing the Chassis Ground Connection
Warning
When installing the unit, the ground connection must always be made first and disconnected last. Statement
42
This unit is to be installed in a restrictive access location and must be permanently grounded to minimum 6
AWG copper ground wire.
Perform the following procedure to ground the Cisco ASR 907 Router using a 2-hole lug and the corresponding
mounting point. Most carriers require a minimum 6 AWG ground connection. Verify your carrier's requirements
for the ground connection.
Procedure
Step 1
If your ground wire is insulated, use a wire-stripping tool to strip the ground wire to 0.5 inch ± 0.02 inch (12.7
mm ±0.5 mm) As shown in the figure below.
Figure 14: Stripping a Ground Wire
Step 2
Slide the open end of your 2-hole ground lug over the exposed area of the ground wire.
Step 3
Using a crimping tool (as specified by the ground lug manufacturer), crimp the ground lug to the ground wire
as shown in figure below.
Figure 15: Crimping a Ground Lug onto the Ground Wire
Step 4
Use a Phillips head screwdriver to attach the 2-hole ground lug and wire assembly to the router with the 2
pan-head Phillips head screws. For a 19-inch EIA rack, attach the 2-hole ground lug to the rear of the router.
Installing the Cisco ASR 907 Router
14
Installing the Cisco ASR 907 Router

Advertisement