The installation must have an
■
adequate cross section.
The mains plug must be freely
■
accessible at all times. If this is not
possible, in order to comply with the
relevant safety regulations, a switch
(all pole disconnection) must be built
into the permanent installation in
accordance with electrical
installation regulations.
If using a residual current circuit
■
breaker, only use one that bears the
following mark: z. The presence of
this mark is the only way to be sure
that it fulfils all the applicable
regulations.
Connect the appliance to the mains
power supply as follows:
Plug the appliance's mains plug into
1.
the designated socket.
Check that the mains plug is in
2.
securely.
Your appliance is now ready to use.
Levelling the appliance
Notes
All appliance feet must stand firmly
■
on the ground.
If appliances are not installed
■
correctly, this may result in noises,
vibrations, uneven drum operation
and/or to residual water leaking out
of the appliance.
Installing and connecting the appliance
Level the appliance as follows:
Loosen the lock nuts using a WAF
1.
17 wrench by turning it in a
clockwise direction.
Turn the appliance feet to level the
2.
appliance. Use the spirit level to
check whether the appliance is level.
Screw the lock nuts tightly against
3.
the housing using a suitable WAF 17
wrench. As you do so, hold the foot
tight and do not adjust its height.
en
17