Installation

The device must be installed by a trained service technician. Please take care, that the socket for the
unit is always accessible. There are no user serviceable items inside the equipment.
If the power supply cable to the unit is damaged, it has to be replaced by the manufacturer, the service
partner or any other qualified person to avoid safety hazard.
6.1

Water Connection

Connecting only to drinkable water
Connect the device to a feed line with an inner diameter of 10 mm. We recommend using a water filter
and a water pressure regulator for the water input. To permit flushing of the filter, a t-piece should be
mounted downstream of the water pressure regulator. The water flow pressure must be minimum 0.2
MPa (2 bar) (mount control pressure gauge on water pressure regulator).
6.2
CO
-Connection
2
You will require minimum a stage-wire pressure regulator with 0.7 MPa (7 bar). Using tubing with an
inner diameter of 4 mm, connect the pressure regulator to the carbonator. Set the CO
0.35 – 0.45 MPa (3.5 to 4.5 bar). The unit include a CO
valves at a CO
-pressure less than 0.3 MPa (3 bar).
2
6.3

Connecting Premix and Postmix Syrup

Connect one tube with an inner diameter of 6 mm to each device connection. Connect the tube end to
the correct cooling coil inputs of the cooler circuit carbonator.
6.4

Connecting Soda Water

Connect the soda water to the forward and backward fittings at the Triton. The inside diameter of the
tubes should be 13 mm.
Cornelius Deutschland GmbH
Document no: TD1011602EN
Version A, 04.07.2019, Index 0