Example Of Several Moby Commands Assigned To One Channel - Siemens MOBY FC 56 Technical Description

Table of Contents

Advertisement

Sample Applications
2nd example
Two commands are directly assigned to each MOBY channel. The MOBY
parameters and the MOBY commands of all SLGs are stored in a "MOBY DB."
A nested structure is used for the declaration.
Declaration view
DB 56:
STRUCT
Channel: ARRAY [1...3]
UDT 10
STRUCT
Command: ARRAY [1...2]
UDT 50
END_STRUCT
END_STRUCT
Figure 5-2

Example of several MOBY commands assigned to one channel

5-8
Data view
MOBY_DB:
Chan. [1]
Chan. [2]
Chan. [3]
... command_start
... init_run
... command_DB_number
... command_DB_address
... ready
... error
Chan. [3] cmd [1]
Chan. [3] cmd [2]
... UID
... command
... filename
... DAT_DB_number
... DAT_DB_address
The MOBY control
parameters and the
commands for each
channel are all located in a
data block for all MOBY
channels.
J31069-D0155-U001-A0-7618