4.2.16
ASM/SLG-STATUS
Parameterizing the command in Command_DB
Table 4-25
UDT 50 "MOBY FH CMD" – ASM/SLG-STATUS
Address
Name
0.0
+0.0
UID
+4.0
command
+5.0
sub_command_1
+6.0
sub_command_2
+7.0
sub_command_3
+8.0
Filename
+16.0
length
+20.0
address_MDS
+22.0
DAT_DB_number
+24.0
DAT_DB_address
+26.0
QUEUE_DB_number
+28.0
QUEUE_DB_address 0
=30.0
Acknowledgment data in the ASM/SLG-STATUS command
Starting at address DAT_DB_address, data block DAT_DB_number contains the
requested data. The data are defined in an UDT so that the user can evaluate this
information.
For the definition of the data structure, see chapter 5.6 (UDT 110/120/130/
140/170).
FC 56
J31069-D0155-U001-A0-7618
Starting
Commentary
Value
DW#16#0
Not used
'S'
MDS command: S = fetch STATUS of the ASM/SLG
B#16#0
Set mode of the ASM/SLG-STATUS command
00H
Read version and last command
01H
Read hardware states of the SLG (only MOBY U)
02H
SLG diagnosis I (only MOBY U)
03H
SLG diagnosis II (only MOBY U)
04H
SLG diagnosis III (only MOBY U)
B#16#0
Not used
B#16#0
Not used
'xxxxxxxx'
Not used
L#1
Not used
W#16#0
Not used
48
Data DB. The status data are written to this
DB.
0
Address of the beginning of the user data in
the data DB
48
Not used
Not used
MOBY Commands