Udt 50 "Moby Fh Cmd" - Read - Siemens MOBY FC 56 Technical Description

Table of Contents

Advertisement

MOBY Commands
4.2.6
READ
Parameterizing the command in Command_DB
Table 4-11
UDT 50 "MOBY FH CMD" – READ
Address
Name
0.0
+0.0
UID
+4.0
command
+5.0
sub_command_1
+6.0
sub_command_2
+7.0
sub_command_3
+8.0
Filename
+16.0
length
+20.0
address_MDS
+22.0
DAT_DB_number
+24.0
DAT_DB_address
+26.0
QUEUE_DB_number
+28.0
QUEUE_DB_address 0
=30.0
Acknowledgment data in the READ command
The user data contained in the acknowledgment in the READ command are written
to the address DAT_DB_number/DAT_DB_address.
The "length" parameter contains the actual length of the read data.
4-16
Starting
Commentary
Value
DW#16#0
MDS number, only MOBY U with multitag
'R'
MDS command: R = Read File
B#16#0
Not used
B#16#0
Not used
B#16#0
Not used
'FILENAME'
File name
Character and/or digit combination in ASCII format
(8 characters, 20H to 7EH).
L#1
Not used
W#16#0
Not used
48
Data DB. The read data are written to this DB.
0
Address of the beginning of the user data in
the data DB
48
Not used
Not used
FC 56