Siemens MOBY FC 56 Technical Description page 55

Table of Contents

Advertisement

Presentation of the MDS data in UDT 100 with sub_command_1 = 01
Table 4-20
UDT 100 "MDS-STATUS"
Address
Name
0.0
+0.0
UID
+4.0
MDS_type
+6.0
sum_subframe_
access
+10.0
sum_searchmode_
access
+12.0
ST_date_Week
+13.0
ST_date_Year
+14.0
battery_left
+16.0
ST
=18.0
FC 56
J31069-D0155-U001-A0-7618
Type
Commentary
STRUCT
DINT
MDS number
BYTE
84 Hex = MDS with 2 kbytes
86 Hex = MDS with 32 kbytes
DINT
Sum of the subframe accesses
INT
Sum of the searchmode accesses
BYTE
Date of the last sleep_time change
(calendar week 1 to 53)
BYTE
Date of the last sleep_time change
(calendar year, example: 01 = 2001)
INT
Remaining battery lifetime in percentage
BYTE
Sleep time Value set on the MDS
Statistically, the tolerance range is equally
distributed for each MDS.
Value
00
01
02
03
04
05
06
07
END_STRUCT
Sleep Time
Tolerance
20 msec
" 6.7 msec
40 msec
" 13.3 msec
80 msec
" 26.7 msec
160 msec
" 53.3 msec
320 msec
" 106.7 msec
640 msec
" 213.3 msec
1280 msec
" 426.7 msec
2560 msec
" 853.3 msec
MOBY Commands
4-25

Advertisement

Table of Contents
loading