Maximum Configuration Of Asm 473 On An Et 200X With - Siemens MOBY FC 56 Technical Description

Table of Contents

Advertisement

A.2
ASM 473
ASM_address:
ASM_channel:
Figure A-3 Maximum configuration of ASM 473 on an ET 200X with sample addressing
Depending on the PROFIBUS master, up to 126 ET 200X modules can be run on
one PROFIBUS branch.
Hardware configuration
The ASM 473 is integrated in the hardware configuration of the SIMATIC Manager
by calling Setup.exe in the directory daten\S7_OM on the "Software MOBY" CD.
Currently, the ASM 473 cannot be integrated in masters of other manufacturers.
SLG connection
An SLG always occupies the two M12 connection sockets X3 and X4 on the
ASM 473. A prefabricated cable makes it easy to connect the SLG. The standard
model of the connection cable is 2 m in length. Other lengths are available on re-
quest. An SLG connection plug with screw-type terminals is available for users
who want to make their own cables. Cables and SLG connection plugs can be
ordered from the MOBY catalog.
FC 56
J31069-D0155-U001-A0-7618
Short Description of the ASM Hardware
Max. of 7 ASM 473s can be
operated in one ET 200X.
8
6
4
2
0
1
1
1
1
1
12
10
1
1
A-5