14 Pin Connector
11-Blue/White
12-Blue
Glow Plug
13-White Park Lights +10amp park light output. At light harness 0volts when
14-Black/ Park Brake
White
4 Pin Connector Square
White/Green
Black
White/Blue
Red
3 Pin Connector Red
1-Green Door Lock
2-Red
12vlt Output
3-Blue
Door Unlock
4-Pink
2nd Unlock
* The centre pin of the keyless entry harness is not to be used for anything
besides plug-in devices such as the VP-1, DL-3, DL-7 and Data Bus Modules.
Overloading this output will damage the remote starter.
3 Pin Connector White
Green*
Auxiliary 1
Pink
Auxiliary 2
Blue
(+) Disconnect (+) Disconnect Or Instant Start Trigger.
*The default setting of the green wire is Negative Horn Output.
Auxiliary outputs are designed to work with the 26xx Series.
2 Pin Connector White
If the Temperature Sensor is installed the Cold Start Mode will operate by
monitoring temperate. If the sensor is not installed the Cold Start Mode will
function as Timer Mode. The temperature sensor can be installed under the
hood strapped to the radiator hose to monitor coolant temperature or left
mounted under the dash to monitor ambient air temperature.
Tach
A/C Tach Signal Input. Used to detect when the
vehicle has started. This wire is connected to the
vehicles coil, fuel injector or crank sensor wire.
Diesel Glow plug input, detects both 12volt and
negative glow plug signals. Programmable input.
Park lights are off, 12volts when park lights are on.
Input to detect Park Brake Switch. Connect to wire at
the switch that switches to (-) when the switch is applied.
LED Output
Dome Light
Siren
Trunk Pin
Door Lock Output - Programmable Menu 1
Output For Door Lock Module Only!
Door Unlock Output - Programmable Menu 1
Output when button #2 is pressed twice.
Programmable Output. Press buttons #1 and #3
Programmable Output. Press buttons #2 and #3
REMOTE VEHICLE STARTER/ALARM
Pulsed negative output for LED activation.
Negative Output For Dome Light Supervision.
Positive Output For Siren.
Negative Input For Trunk Pin Switch.