Data; Parameter Data - Balluff BTL5-T110 Series Technical Description

Configuration and profibus connection transducer class 3/4
Table of Contents

Advertisement

Available languages

Available languages

BTL5-T110...
Configuration and Profibus Connection –
Transducer Class 3/4
7

Data

7.1

Parameter data

The Parameter telegram consists
of the encoder-specific
parameters, the parameters for
clock synchronism as well as
manufacturer-specific parameters.
Byte Number
Parameter
0
Struct len
1
Struct type
2
Slot nbr
3
reserved
4 Bit 0
Code Sequence
4 Bit 1
Class 4 Functionality
4 Bit 2
Offset Control
4 Bit 3
Scaling Function Control
4 Bit 4
Extended Diagnostic
4 Bit 5-7
reserved
5-8
Measuring steps
9-12
Total Meas. Range in
Meas. Steps
13
max.tol.failures of lifesign
14
Velocity resolution units
15-20
reserved
Table 7-1: Encoder parameter data
Velocity resolution units
Steps / 1000 ms
Steps / 100 ms
Steps / 10 ms
Table 7-2: Velocity resolution
38
english
Data type
Unsigned8
Unsigned8
Unsigned8
Unsigned8
Bit
Bit
Bit
Bit
Bit
Unsigned32
Unsigned32
Unsigned8
Unsigned8
Value
0x00
0x01
0x02
Default
Remark
0x15
Block size
0x81
Encoder Parameter
0x00
Input Module
0x00
in units of nm (see Parameter
Number 60001)
➥ ➥ ➥ ➥ ➥ Table 7-2
0x00
"Speed resolutions"
Do not change