Installation - U-Line ICE-MAKER User Manual

Ice-makers, combos, refrigerators, 75 bev beverage center
Table of Contents

Advertisement

SITE PREPARATION
Your U-Line product is designed to be installed in a wall or under a
counter or freestanding.
The 75 BEV must be ordered for right or left hand door. The
75 BEV doors are not reversible. Any reference to revers-
ing the door, does not apply to the 75 BEV.
1. Position the unit on a flat, level surface, capable of supporting the
entire weight of the unit. Remember the unit will be significantly
heavier once it is fully loaded.
It is extremely important that the unit is level. If it is not
level, the ice mold will not fill evenly. This can cause a reduc-
tion in ice rate, uneven sized cubes or water spilling into the
storage area which will cause the ice in the bin to melt pre-
maturely. Remember that floors near drains have a ten-
dency to slope towards the drain.
2. The surrounding air temperature must be at least 50°F (10°C) but
must not exceed 110°F (40°C).
3. The unit must not be located near heat-generating equipment or in
direct sunlight.
4. The unit must be located to allow clearance for water, drain and
electrical connections in the rear when applicable.
5. Connect the unit to its own grounded and polarized 115 VAC, 60
Hz, 15A circuit (normal household current).
6. Avoid connecting the unit to a Ground Fault Interruptor (GFI). GFIs
are prone to nuisance tripping which will cause the unit to shut
down. GFIs are generally not used on circuits which power
equipment that must run unattended for long periods of time.
7. The unit must be installed according to your local codes and
ordinances.

INSTALLATION

NOTE
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

75 bevBi-95Bi-98Sp1875a29ff ... Show all

Table of Contents