U-Line ICE-MAKER User Manual page 52

Ice-makers, combos, refrigerators, 75 bev beverage center
Table of Contents

Advertisement

User's Manual
Problem
The unit is not
cold enough (cont.) blocked
The unit is not cold The door was left open
enough (Frost free
units only)
The unit frosts
up
Water is leaking
out the back
of the unit
Ice cubes
sticking together
Noise during
operation
Possible Cause
Airflow to front grille
Temperature not set
cold enough
causing the evaporator
behind the back wall to
fill with frost preventing
proper air flow and
cooling.
Unit is manual
defrost model
Door gasket not
sealing properly
High ambient
temperatures or
humidity
Water supply
connection leaking
Door gasket not
sealing properly
Infrequent use of cubes
Copper water supply
tubing contacting
internal components
Certain sounds are
normal.
Fan blade touching
obstruction (wiring,
foam insulation, etc.)
50
Remedy
Airflow must not be
obstructed to front grille.
See INSTALLATION or
CLEANING AND
MAINTENANCE.
Turn control knob
CLOCKWISE to set
temperature colder.
Allow 24 hours for
temperature to stabilize.
Turn off the unit to manually
defrost the evaporator.
See DEFROSTING.
Models SP18, 95, 98,
and Combo 29A and
75A are manual defrost.
Refer to DEFROSTING.
Adjust door. See
ALIGNING THE DOOR.
Defrost unit manually.
See DEFROSTING.
Tighten fitting. See
CONNECTING THE
WATER SUPPLY.
Adjust door. See
ALIGNING THE DOOR.
Break apart cubes.
Carefully bend tubing
away from cabinet and
components.
Soft sounds from the fan
and water/dropping
sounds from the ice maker
will be heard.
Remove obstruction.

Advertisement

Table of Contents
loading

This manual is also suitable for:

75 bevBi-95Bi-98Sp1875a29ff ... Show all

Table of Contents