Sprayer Status Indicator
Red
Yellow
ti19361a
*NOTE: The sprayer status indicator light is visible for 10 seconds after the trigger is released.
8
No light
Solid Red
Flashing Red
Solid Yellow
Flashing Yellow
Solid red and solid yellow Locked motor.
Normal operation.
Battery is too hot. Unit will
shut down until battery has
cooled.
Liquid has contacted control
board.
Motor is too hot and will shut
down if heavy use continues.
Unit will shut down until motor
has cooled.
Battery is low or
battery is too cold.
High pressure signal. Gun will
shut down after 1.5 seconds.
Operation
No action required.
Change battery.
Allow battery to cool.
Allow unit to dry.
Increase tip size.
Turn down pressure.
Let unit cool down.
Charge battery.
Warm up battery.
Turn pressure control
counter-clockwise to reduce
pressure.
Increase tip size.
Material is too thin--do not thin
as much.
Bring sprayer in to service cen-
ter for diagnostics.
3A2308A