Controls and Indicators
Motor/Pump Control Function Knob
Status
Codes
F
. 2: Controls and Indicators
IG
Power Switch
Powers the system on and off.
Motor/Pump Control Function Knob
Use the knob to select desired function.
Icon
Setting
Park
Slow Recirc
Fast Recirc
Static Mix
Spray
3A5743C
+
-
Function
Stops motor and
automatically parks pumps.
Slow recirculation speed.
Fast recirculation speed.
Use fluid flow settings 1-5 to
dispense polyurea joint-fill
materials through a static
mixer.
Use fluid pressure settings
6-10 to spray polyurethane
foam.
Status Indicator
-
-
STATUS Indicator
Indicates the system status, including power and error
codes.
•
Indicator steady on: power switch is turned on.
•
Indicator blinking: If an error occurs, the status
indicator light will blink one to seven times to
indicate a specific status code, pause, and then
repeat. The following table provides a brief
description of each status code. For more detailed
information and corrective action, see Status
Codes on page 21.
Table 1: Status Codes
(also located on the front of the Reactor)
Code
Code Name
1
Pressure imbalance between A and B sides
2
Unable to maintain pressure setpoint
3
Pressure transducer A failure
4
Pressure transducer B failure
5
Excessive current draw
6
High motor temperature
7
No cycle counter switch input
NOTE: The default is to shut down if a status code
indication occurs. Codes 1 and 2 may be set to disable
automatic shutdown if desired; see page 22. You cannot
set the other codes.