The NFC tag is not present (1520)

The operating unit battery is empty (1478)

INFORMATION
Changing the battery
Setting the date/time
Description
It is not possible to access the digital key (NFC tag).
Troubleshooting
Unplug digital key and then reinsert. De-energize unit beforehand.
Change digital key.
Replace control board.
Description
The date and time are lost after the unit is switched on or they reset.
HACCP and log data are no longer saved in a form that can be
evaluated.
Replacement requires disassembly of the operating unit.
Troubleshooting
Battery type
Required battery: Button cell CR1220 3 V.
De-energizing the unit
Removing the control unit
Detaching lines to the operating unit
Remove rear cover from touchscreen. This requires removing the
four fastening screws.
Change the battery.
Reassembly is carried out in reverse order.
Restoring the power supply
Set the date and time in the basic settings or service menu.