DURKOPP ADLER 911-210 Additional Instructions page 17

Neat seam beginning (nsb)
Hide thumbs Also See for 911-210:
Table of Contents

Advertisement

Assembling the neat seam beginning (NSB)
Assembling the throat plate holder and adjusting the needle guide
Fig. 11: Throat plate holder (2)
(1) - Screws
(2) - Throat plate holder
(3) - Needle guide
To assemble the correct throat plate holder and adjust the needle guide:
1. Tighten the throat plate holder (2) using the screws (1).
2. Assemble the throat plate (5).
3. Lock the machine in place at the looping stroke position.
Fig. 12: Throat plate holder (3)
4. To adjust the needle guide (3), turn the screw (4).
5. Use a sheet of paper to check the distance between needle and needle
 The space between needle and needle guide (3) must just be wide
Additional Instructions 911 - 00.0 - 05/2020
• To move the needle guide closer to the needle:
Turn screw (4) clockwise
• To move the needle guide further away from the needle:
Turn screw (4) counterclockwise
guide (3) and adjust it if necessary.
enough to allow a sheet of paper to pass through.
(4) - Screw
(5) - Throat plate
15