ZyXEL Communications P-334WT Support Notes page 70

Hide thumbs Also See for P-334WT:
Table of Contents

Advertisement

Set Name= NAT_SET
Idx
Local Start IP
IP
Type
---
---------------
---------------
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
We will just look at the differences from the previous menu. Note that, this screen is not read only, so
we have extra Action and Select Rule fields. Not also that the [?] in the Set Name field means that this is
a required field and you must enter a name for the set. The description of the other fields is as described
above. The Type, Local and Global Start/End IPs are configured in Menu 15.1.1 (described later) and
the values are displayed here.
Field
Description
Enter a name for this set of rules. This is a required field.
Set Name
that if this field is left blank, the entire set will be deleted.
They are 4 actions. The default is Edit. Edit means you want to edit a
selected rule (see following field). Insert Before means to insert a new
rule before the rule selected. The rule after the selected rule will then be
Action
moved down by one rule. Delete means to delete the selected rule and
then all the rules after the selected one will be advanced one rule. Save
Set means to save the whole set (note when you choose this action the
Select Rule item will be disabled).
Menu 15.1.1 - Address Mapping Rules
Local End IP
---------------
------
Action= Edit
Press ENTER to Confirm or ESC to Cancel:
Global Start IP
---------------
, Select Rule= 0
Please note
Global End
Option
Rule1
Edit
Insert Before
Delete
Save Set

Advertisement

Table of Contents
loading