Omron F300 Installation Manual page 70

Visual inspection system
Table of Contents

Advertisement

Maintenance
Procedure
1, 2, 3...
Important 1. Replace the battery within 5 minutes to prevent loss of the memory con-
1. Turn off the F300 System power. If the F300 System is already off, turn it on
for 10 seconds then turn it off again.
2. Insert a small flat-blade screwdriver into the cut-out at the top of the battery
cover and gently remove the cover.
3. Detach the battery connector. Cut the battery retaining band with nippers
and pull the battery from the connector.
4. Secure the new battery to the cover with the retaining band supplied and
attach the battery connector.
5. Return the battery cover to its original position.
tents. If replacement will take more than 5 minutes, transfer the scene,
system, and shading master data to a memory card or a computer
connected to the RS-232C port before replacing the battery.
2. To prevent damage to or leakage from the battery, do not short, recharge,
disassemble, or heat the battery.