F300-L12E Ovl Unit - Omron F300 Installation Manual

Visual inspection system
Table of Contents

Advertisement

Expansion Units
Specifications
General Specifications
Performance
Specifications
Dimensions and Weight

2-2-2 F300-L12E OVL Unit

26
Ambient temperature
Ambient humidity
Ambient environment
Storage temperature
Degree of protection
Strobe connections
Strobe trigger output
Strobe flash error input
The following diagram provides the external dimensions and weight of the
F300-FS Strobe I/F Unit. Unless otherwise noted, values are in millimeters
(mm).
250
Front cover
The OVL Unit extends the capabilities of the F300 to allow it to be operated using
OVL (OMRON Vision Language). OVL was developed specifically for optical
recognition and image measurement to permit more sophisticated
measurements with a BASIC-like language. The OVL Unit's keyboard also al-
lows data input and system operation from the Menu mode in the same fashion
as is possible from the Console.
0°C to 50°C
35% to 85% RH (no condensation)
No corrosive gases
–25°C to 65°C
IP20 (in-panel)
4 max.
20 mA max. per Unit, photocoupler output
Photocoupler input
Input ON current:
3 mA min.
Input OFF current: 1.5 mA max.
34.6
133.5
Weight: approx. 400 g