Crankcase Breather - Honda Dream DX CD110 Owner's Manual

Table of Contents

Advertisement

2. Operate the kickstarter several times to aid
in complete draining of the remaining oil.
3. Check that the sealing washer on the drain
bolt is in good condition and install the
bolt. Replace the sealing washer every
other time the oil is changed, or each
time if necessary.
Oil Drain Bolt Torque:
24 N.m (2.4 kgf.m, 17 Ibf.ft)
If a torque wrench is not used for this
installation, see your Honda dealer as soon
as possible to verify proper assembly.
4. Fill the crankcase with recommended
grade oil; approximately:
0.8 L (0.8 US qt, 0.7 Imp qt)
5. Install the oil filler cap/dipstick.
6. Start the engine and let it idle for 3-5
minutes.
7. 2-3 minutes after stopping the engine,
check oil level with dipstick. It should be
on upper level mark of the dipstick with
vehicle standing upright confirm level
ground. Make sure there are no oil leaks.
40
CD110 Dream DX

CRANKCASE BREATHER

Refer to the Safety Precautions on Page 34.
1. Remove the left side cover (page 26).
2. Remove the "Crankcase Breather Tube
" (1) from the air cleaner housing and
drain deposits from the "Air cleaner drain
tube" (2) into a suitable container.
3. Reinstall the crankcase breather tube.
Service more frequently when riding in
rain,or at full throttle.
(1)
(1) Crankcase Breather Tube
(2) Air Cleaner Drain Tube
Honda Motorcycle & Scooter India Pvt. Ltd.
(2)