2. Check the front-panel LEDs as the device is powered on to be sure the PWR LED is lit. If
not, check that the power cable is correctly plugged in.
Connect the AC power cord to the back of the switch, and then connect the cord to a power
outlet.
Danger:
Using power cords with a proper grounding path
Use only power cords that have a grounding path. Without a proper ground, a person
who touches the switch is in danger of receiving an electrical shock. Lack of a grounding
path to the switch can result in excessive emissions.

AC power specifications

The following table describes the AC power specifications for the ERS 3500 Series.
Model
3510GT
3510GT-PWR+
3524GT
3524GT-PWR+
3526T
3526T-PWR+
3549GTS
3549GTS-PWR+
3550T
3550T-PWR+
AC power cord specifications
To connect AC power to the switch, you need an appropriate AC power cord as described in the
following table, also see the following table for plug specifications.
December 2017
Input current
Maximum 0.18 A
Maximum 2.1 A
Maximum 0.28 A
Maximum 5.0 A
Maximum 0.28 A
Maximum 5.0 A
Maximum 0.71 A
Maximum 4.91 A
Maximum 0.83 A
Maximum 6.8 A
Installing Ethernet Routing Switch 3500 Series
Input voltage
Power consumption
(rms)
100–240 VAC at
Maximum 18 W
50–60 Hz
100–240 VAC at
Maximum 210 W
50–60 Hz
100–240 VAC at
Maximum 28.5 W
50–60 Hz
100–240 VAC at
Maximum 475 W
50–60 Hz
100–240 VAC at
Maximum 28.5 W
50–60 Hz
100–240 VAC at
Maximum 473 W
50–60 Hz
100–240 VAC at
Maximum 65 W
50–60 Hz
100–240 VAC at
Maximum 484 W
50–60 Hz
100–240 VAC at
Maximum 35 W
50–60 Hz
100–240 VAC at
Maximum 504 W
50–60 Hz
Thermal rating
61Btu/h
maximum
156 Btu/h
maximum
95 Btu/h
maximum
357 Btu/h
maximum
95 Btu/h
maximum
350 Btu/h
maximum
223 Btu/h
maximum
424 Btu/h
maximum
118 Btu/h
maximum
456 Btu/h
maximum