Download Print this page

Specifications - Traulsen RDT132WPUT-HHS Specification Sheet

R series, a series pass-thru refrigerator-freezer

Advertisement

Project
Model Specified:
Construction, Hardware and Insulation
Cabinet exterior front, one piece sides, louver assembly and doors are constructed
of 20 gauge stainless steel with #4 finish. Cabinet interior and door liners are
constructed of stainless steel (anodized aluminum in the A-Series). The exterior cabinet
top and bottom are constructed of heavy gauge aluminized steel. A set of four (4)
adjustable 6" high stainless steel legs are included.
Doors are equipped with a gasket protecting metal door pan, removable plug
cylinder locks and guaranteed for life cam-lift, gravity action, self-closing metal, glide
hinges with stay open feature at 120 degrees. Hinges include a concealed switch to
automatically activate the interior incandescent lighting. Guaranteed for life, work
flow door handles are mounted horizontally over recess in door which limits
protrusion from door face into aisleways. Doors have seamless, polished metal
corners.
Easily removable for cleaning, vinyl magnetic door gasket assures tight door seal.
Anti condensate heaters are located behind each door opening.
Both the cabinet and door(s) are insulated with an average of 2" thick high density,
non-CFC, foamed in place polyurethane.
DIMENSIONAL DATA
R/ADT132WPUT R/ADT232WPUT R/ADT332WPUT
Net capacity total cu. ft.
20.6 (584 cu l)
Net capacity refrig. cu. ft.
10.5 (297 cu l)
Net capacity freezer cu. ft. 10.1 (286 cu l)
Length - overall in.
29
(75.9 cm)
7
8
Depth - overall in.
37
15
16
Depth - over body in.
32 (81.3 cm)
Depth - doors open 90° in. 83
3
(211.5 cm)
8
Clear door width in.
21
(53.6 cm)
1
8
Clear half-door height in.
27
(69.9 cm)
1
2
Clear full-door height in.
n/a
Height - overall on 6" legs 83
(211.5 cm)
1
4
No. Standard Shelves
2
Shelf area total sq. ft.
28.0 (2.6 sq m)
1
Shelf area refrig. sq. ft.
14.0 (1.3 sq m)
1
Shelf area freezer sq. ft.
14.0 (1.3 sq m)
1
RDT Net Wt. lbs.
455 (206 kg)
ADT Net Wt. lbs.
405 (184 kg)
ELECTRICAL DATA
Voltage
115/60/1
Feed wires with Ground
3
Full load amperes
11.0
REFRIGERATION DATA
Refrigerant - Refrigerator
R-134a
Refrigerant - Freezer
R-404A
BTU/HR H.P. - Refigerator
1130 (
2
BTU/HR H.P. - Freezer
1440 (
2
NOTE: Figures in parentheses reflect metric equivalents.
1=
Area of standard shelf compliment only, does not include storage area of additional shelves or available on
cabinet bottom.
2=
Based on a 90 degree F ambient and 20 degree F evaporator for the refrigerated section and a 90 degree
F ambient and -20 degree F evaporator for the freezer section.
3=
For approximate remote weights deduct 40 lbs. from respective net or gross weight. For other information
on remote models, please refer to spec sheet 12-2.
NOTE: When ordering please specify: Voltage, Hinging, Door Size, Options and any
additional warranties.
Continued product development may necessitate specification changes without notice.
Part No. TR35782 (revised 1/07)
TRAULSEN
SECTION
4401 BLUE MOUND RD.
PHONE 1 (800) 825-8220
3-4
Website: www.traulsen.com
45.0 (1275 cu l) 69.3 (1962 cu l)
23.2 (657 cu l)
47.5 (1346 cu l)
21.8 (657 cu l)
21.8 (657 cu l)
58 (147.3 cm)
86
1
8
(96.4 cm)
37
15
(96.4 cm) 37
15
16
32 (81.3 cm)
32 (81.3 cm)
83
3
(211.5 cm)
83
3
8
8
21
(53.6 cm)
21
1
1
8
8
27
(69.9 cm)
27
1
1
2
2
57
(146.3 cm) 57
5
5
8
8
83
(211.5 cm)
83
1
1
4
4
6
9
37.6 (3.49 sq m) 56.4 (5.23 sq m)
18.8 (1.75 sq m) 37.6 (3.49 sq m)
18.8 (1.75 sq m) 18.8 (1.75 sq m)
705 (320 kg)
1030 (467 kg)
615 (279 kg)
900 (408 kg)
115/60/1
115/60/1
3
3
16.0
22.6
R-134a
R-134a
R-404A
R-404A
HP)
1730 (
HP)
4200 (
1
1
5
4
HP)
2170 (
HP)
2160 (
1
1
3
2
NOTES
Quantity

Specifications

Refrigeration System
A top mounted, self-contained, balanced refrigeration system using R-134a and
R-404A refrigerants is conveniently located behind the one piece louver assembly.
Two and three section models feature an easy to clean front facing condenser,
thermostatic expansion valve, air-cooled hermetic compressor, plenum effect blower
coil, large, high humidity evaporator coil located outside the food zone and a top
mounted non-electric condensate evaporator. One section models feature an
interior mounted coil and bottom mounted condensate evaporator.
Biased return air duct protects against introduction of warm kitchen air, promoting
even temperature maintenance and efficient operation.
A 9' cord and plug is provided standard on one and two section models. Standard
operating temperatures are 34 to 38°F for the refrigerator compartment and 0
to -5°F for the freezer compartment.
Controller
The easy to use water resistant INTELA-TRAUL
supplied standard. Unit is NAFEM Data Protocol communication (NDP) ready.
Optional hardware required to be NDP compliant. Third party software required for
network connection. It includes a 3-Digit LED Display, Fahrenheit or Celsius
Temperature Scale Display Capability, and an RS485 data port. In addition it
includes audio/visual alarms for: Hi/Lo Cabinet Temperature, Door Open, Clean
Condenser, Evaporator Coil and Discharge Line Sensor Failures, and Power Supply
Interruption. A separate control is provided for both the refrigerator and freezer
compartments.
(218.8 cm)
Interior
Standard interior arrangements include three (3) chrome plated wire shelves per
(96.4 cm)
16
section, mounted on shelf pins (one section models are supplied standard with two
chrome plated shelves). Shelves are full-width, and do not have any large gaps
(211.5 cm)
between them requiring the use of "bridge" or "junior shelves." Recommended load
limit per shelf should not exceed 225 lbs. Optional tray slides may be
(53.6 cm)
purchased in combination with, or in lieu of these. Both standard and optional
(69.9 cm)
interior arrangements are completely installed at the factory.
(146.3 cm)
Warranties
(211.5 cm)
Both a one year parts and labor warranty and a five year compressor warranty (self-
contained models only) are provided standard. An optional 2
and labor warranty is also available. In addition the INTELA-TRAUL
warranted by a two year parts and labor warranty.
In order to assure optimum performance, the condensing unit MUST have an adequate supply of
HP)
1
2
air for cooling purposes. Therefore, the operating location must either have a minimum of 12"
HP)
1
clearance overhead of the condensing unit or allow for unrestricted air flow at the back of the unit.
2
Clearance of at least 12" above is required in order to perform certain maintenance tasks.
FT. WORTH, TX 76106
FAX-MKTG. 1 (817) 624-4302
Item #
CSI Section 11400
microprocessor control system is
®
Equipped With One NEMA 5-15 P Plug
(1 section models only)
Equipped With One NEMA 5-20 P Plug
(2 section models only)
NOTE: Full load amps and plug style may vary depending
on electrical options chosen and condensing unit employed.
REQUIRED CLEARANCES
nd
year extended parts
controls are
®

Advertisement

loading

This manual is also suitable for:

Adt132wput-hhsAdt232wput-fhsAdt232wput-hhsAdt332wput-fhsAdt332wput-hhsRdt232wput-fhs ... Show all