III. a - EQUIPMENT SPECIFICATIONS:
DIMENSIONS
Length - Overall in.
Depth - Overall in.
Height - Overall in.
1= Height shown to work top, height over
control is 53".
III. b - OPERATING DATA:
DATA
1
H.P.
1
BTU
2
H.P.
BTU (-10 degree F evaporator)
1
Refrigerant
2
Refrigerant
1
Refrigerant Charge
2
Refrigerant Charge
Cond Unit Amp Draw (RLA)
Cond Unit Amp Draw (RLA)
Unit Voltage
Full Load Amps
1= Self-Contained Holding or Primary Compressor.
2= Blast Chilling or Secondary Compressor.
3= These may vary depending upon type of remote condensing
III. c - REFRIGERATION SYSTEM INSTALLATION:
All Traulsen blast chillers, with the exception of model
RBC50, require the use of a floor drain or floor
mounted
condensate
removal. Refer to "Section III. h" of the blast chill
owner's manual for more information.
Remote refrigeration installation requirements apply
only to models RBC200 and RBC200RT. A remote con-
densing unit, operating on R-404A refrigerant, is re-
quired for Blast Chill operation on these models. The
remote condensing unit(s) should be capable of pro-
viding 18,700 BTU/hr @ -10 F suction and 90 F ambi-
ent at the evaporator coils of the Blast Chill section.
4 HP air-cooled and 3 HP water-cooled remote con-
densing units are available from Traulsen as an op-
tional accessory, but please note that these are rated
for use only within a 25 foot radius of the cabinet.
III. SPECIFICATIONS
RBC50
RBC50
(2003 -2007)
(2008 - CURRENT)
57-1/2
54
34-1/4
34-7/16
1
34
34
RBC50
RBC50
(2003 -2007)
(2008 - CURRENT)
1/2 HP
1 HP
1350
4400
1/2HP
n/a
2
1350
n/a
R-404A
R-404A
R-404A
n/a
20 oz.
28 oz.
20 oz.
n\a.
1
n/a
11.7
2
n/a
n/a
115/60/1
115/60/1
9.3 (per unit)
13.3
evaporator
for
condensate
RBC100 RBC200 RBC200RT
34
48-1/2
48-1/2
41-5/8
37-1/2
41-1/8
80-1/8
89-1/2
89-1/2
RBC100 RBC200 RBC200RT
1/2 HP
3/4 HP
3/4 HP
2280
3880
3880
3
3
1-1/4 HP n/a
n/a
5460
18,700
18,700
R-404A R-404A R-404A
3
3
R-404A n/a
n/a
49 oz.
20 oz.
20 oz.
3
3
64 oz.
n/a
n/a
9.6
15.2
15.2
5.7
30.7
30.7
1
220/115 115/60/1
115/60/1
1
1
15.1
15.2
15.2
III. c - REF'N SYSTEM INSTALLATION (CONT):
Actual capacity of the remote condensing unit and line
sizing will depend on the length and layout of the con-
necting piping from the remote condensing unit to the
Blast Chill unit. These utilize a 1/2" liquid and 1-1/8"
suction lines. Proper line sizing should be defined by a
qualified refrigeration engineer or technician.
The low pressure cut-out of the remote condensing unit
should be adjusted to obtain an evaporator coil
temperature NO LOWER THAN -
the connecting piping is 40 feet or less, the condens-
ing unit low pressure cut-out settings will be approxi-
mately 15 +/- 2 PSIG cut-out and 25+/- 3 PSIG cut-in.
For more information please contact the factory (800-
825-8220).