= ER
Replies When an Error Has Occurred
Function:
Replies when an error has occurred.
Syntax:
stxER:a;
a: Error number
0
1
2
3
4
5
6
7
8
9
10
20
21
100 The AR-3000R received a 2Q or 3Q command even though the specified phrase
101 A PQ, QQ or TQ command is used to request output even after the setting
102 The AR-3000R received an RE command even though it was not in recording
202 There is no time information for the specified phrase.
300 The command is not compatible with the Dual Mono mode.
301 Specify a time parameter within the phrase recording time.
302 Phrases other than audio phrases cannot be specified.
303 Phrases other than MIDI phrases cannot be specified
304 Phrases other than audio phrases, MIDI phrases, and pattern phrases cannot be
305 There is no blank phrase.
306 In the Delete mode, only editing commands are processed.
307 Before sending an RL command, first specify a phrase with the PA command.
Syntax error.
This error occurs when correct reception was not possible, such as when the
syntax of the command was incorrect or inappropriate.
The specified phrase does not exist, or the phrase number is incorrect. This error
will also be output if a phrase number is specified for a card which is not
inserted.
Busy error.
The AR-3000R is currently recording or playing back. When the AR-3000R is
recording or playing back, it will process only the following commands.
During Play
During Play Pause
During Recording standby
During Recording
During Recording Pause
An editing command was received when the AR-3000R was not in Delete mode.
This error occurs if a setting/delete/record command is transmitted while the
write protect switch of the card is ON.
This error occurs when the total number of phrases specified by the PA, PU, or
CE commands exceeds the maximum value (100), or when the specified
parameter value is outside of the limit of the maximum value.
This error occurs when the characters being set for a phrase name or card name
exceed the maximum value.
This error occurs when characters other than numerals (0 - 9) are used to specify
an integer.
This error occurs when you attempt to specify a previously recorded phrase as a
pattern phrase.
This error occurs when you attempt to record or copy a phrase on an already
recorded phrase.
There is no remaining card capacity.
The command could not be executed for some other reason.
Unsupported card or incorrect format. Format the card by panel operation.
was not a pattern phrase.
information of the last phrase has been output.
standby mode.
specified.
Control commands
Request commands
PA , ST , PE
AC
PA , ST , PE , RL
AC
RE, ST
AC
PA , ST, PE
AC
PA , ST, PE
AC