Operation
How to change from the operation mode to the configuration mode:
Precondition: You are in the operation mode.
The display shows as running text the manufacturer's name and the version number
of the control electronics or a text determined individually by you.
How to exit the configuration mode:
In the present example, the second level of the menu tree "Setup" was selected.
The display of the control electronics shows "Sprache/Language" as running text.
How to change a parameter with the help of the control keys:
CAUTION! Uncontrolled system behavior! When parameters are changed with the
help of the control keys of the control electronics, the entries are not checked for
the signal "enable active".
Bosch Rexroth AG, VT-VPCD, RE 30028-B/09.13
Hyquip Limited New Brunswick Street Horwich Bolton Lancashire BL6 7JB UK
Company Registered in England No: 4167649 VAT Registration No: 732 5692 25 BS EN ISO 9001:2008 No: LRQ 0964389
The control electronics is in the configuration mode "EDIT Parameters".
Press the control keys "ENT" and "ESC" simultaneously (exception: for "EDIT
Parameters", see above) and hold them down (for at least 2 seconds) until
"Setup" is shown on the display of the control electronics.
The control electronics is now in the setup mode.
Press the "ESC" control key.
The display shows "Setup" as running text.
Press the control key "ESC".
The display shows as running text the manufacturer's name and the version
number of the control electronics or a text determined individually by you.
If no entry is made within a minute in the configuration mode, the control
electronics automatically changes to the next higher level until the operation
mode is reached.
The control electronics VT-VPCD is fully operable in the configuration mode.
Do not change one or several analog inputs from voltage to current or from
current to voltage. When you change the type of one or several analog inputs, the
active value is not interpreted as desired.