Pressure transducer side A
and/or side B
Hyquip Limited New Brunswick Street Horwich Bolton Lancashire BL6 7JB UK
Company Registered in England No: 4167649 VAT Registration No: 732 5692 25 BS EN ISO 9001:2008 No: LRQ 0964389
+44 (0)1204 699 959
enquiries@hyquip.co.uk
5
4
3
1
2
Fig. 19: Connection of swivel angle transducer MCP-40/4742
The transducer is connected by means of soldered connections.
Up to a length of 50 m we recommend the use of 3 x 0.5 mm² cables of type LiYCYCY
as connection cable. When double-shielded cables are used, the outer shield can be
terminated at the entrance in the control cabinet, the outer shield can be terminated
at the control electronics.
For the voltage interface, pressure transducers of type HM 20 -2X/...H-K35 are used.
Pressure transducer cables must be shielded.
Cable type for the voltage interface: LiCYC 4 x 0.25 mm
Voltage interface (HM 20)
z30
1
b22
2
4
3
b24
z32
z10
When 2 pressure transducers are used:
z30
1
2
4
b6
3
b8
z32
z10
Fig. 20: Connection of pressure transducers HM 20 with voltage interface
www.hyquip.co.uk/web/index
b28
b32
b12
b28
b10
z10
2
up to a length of 50 m.
p
B
p
A
RE 30028-B/09.13, VT-VPCD, Bosch Rexroth AG
Installation
35/60