Acquisition commands for mode setting values for clogged nozzle detected signal (output)

[Format]
~H(CNA,D
[Parameter] None
[Function]
Acquire the mode setting values for the clogged nozzle detected signal.
Return value after
executing this command
0
1
2

Acquisition commands for mode setting values for head maintenance signal (output)

[Format]
~H(CNA,M
[Parameter] None
[Function]
Acquire the mode setting values for the head maintenance signal.
Return value after
executing this command
0
1
2
Clogged nozzle detected signal (pin 24) OFF (not output)
Clogged nozzle detected signal (pin 24) set to Normal: High,
When nozzle clogged: Low
Clogged nozzle detected signal (pin 24) set to Normal: Low,
When nozzle clogged: High
Head maintenance signal (pin 21) OFF (not output)
Head maintenance signal (pin 21) set to Normal: High,
When head maintenance is in progress: Low
Head maintenance signal (pin 21) set to Normal: Low,
When head maintenance is in progress: High