Installer manual Fleck 5800 XTR - Programming
Screen name Parameters
Format,
Free-form
Assistance
text
name
Format,
Free-form
Assistance
text
phone
Format,
Interval
Assistance
interval
Valve
System
Valve
Regen type
Media
volume
Salt dosage
BLFC size
64 / 126
Values
A - Z and space
0 - 9 and space
Month based: 1 - 60
Regen based: 5 -
2000
OFF
4
5800
5810
5812
Time clock
Softener immediate
Softener delayed
Filter immediate
Filter delayed
3
0.25 to 999 ft
1 to 9999 litres
3
3 to 18 lbs/ft
50 to 290 g/litre
0.125 gpm
0.250 gpm
0.500 gpm
1.000 gpm
Notes
Name of service provider to display when
viewing the assistance screen. 24 character
limit.
Phone number of service provider to display
when viewing the assistance screen.
14 character limit.
Set to automatically display the assistance
screen after a certain number of months or
regenerations.
Type 4 (single system) is currently the only
available selection.
Select the type of valve to be installed.
Regeneration types are described in detail on
Regeneration flows [}Page 44].
Additional Valve screen parameters are
dependent upon selected regeneration type.
Not all parameters will be displayed.
Softener delayed regeneration type has four
reserve options (fixed %, fixed volume,
variable reserve, weekly reserve). The
control will display additional configuration
options depending on the selected reserve
type.
Only required on softener metered
regeneration types.
Ref. MKT-IM-006 / E - 12.11.2019