Extron electronics DMS 1600 Setup Manual

Extron electronics DMS 1600 Setup Manual

Configurable digital video matrix switchers
Hide thumbs Also See for DMS 1600:

Advertisement

Quick Links

Setup Guide
Matrix Switchers
DMS 1600, DMS 2000,
DMS 3200, DMS 3600
Configurable Digital Video Matrix Switchers
68-1829-50 Rev. D
10 19

Advertisement

Table of Contents
loading

Summary of Contents for Extron electronics DMS 1600

  • Page 1 Setup Guide Matrix Switchers DMS 1600, DMS 2000, DMS 3200, DMS 3600 Configurable Digital Video Matrix Switchers 68-1829-50 Rev. D 10 19...
  • Page 2 Safety Instructions Safety Instructions • English Istruzioni di sicurezza • Italiano AVVERTENZA: Il simbolo, , se usato sul prodotto, WARNING: This symbol, , when used on the product, is serve ad avvertire l'utente della presenza di tensione intended to alert the user of the presence of uninsulated dangerous voltage within the product’s enclosure that may non isolata pericolosa all'interno del contenitore del prodotto che può...
  • Page 3 All trademarks mentioned in this guide are the properties of their respective owners. The following registered trademarks, registered service marks, and trademarks are the property of RGB Systems, Inc. or Extron Electronics (see the current list of trademarks on the Terms of Use page at www.extron.com):...
  • Page 4 The product is intended to be used with the fiber optic cables fully installed. This product meets the applicable requirements of IEC 60825-1, Edition 1 (2007). Any service to this product must be carried out by Extron Electronics and its qualified service personnel.
  • Page 5 Conventions Used in this Guide Notifications the following are used: WARNING: A warning indicates a situation that has the potential to result in death or severe injury. ATTENTION: Attention indicates a situation that may damage or destroy the product or associated equipment. NOTE: A note draws attention to important information.
  • Page 7: Table Of Contents

    Removing and Installing an I/O Board or Blank Panel ... 29 Removing and Installing a Power Supply Module (DMS 1600 and DMS 3600) ..31 Removing and Installing a Fan (DMS 1600 and DMS 3600) ..32 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Contents...
  • Page 8 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Contents...
  • Page 9: Introduction

    Load and start the Matrix Switchers Control Program • Connect to the built-in HTML pages to operate the switcher • Reconfigure the switcher by adding or removing boards, power supplies, and fans DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Introduction...
  • Page 10: About The Dms Matrix Switchers

    Extron Matrix Switchers Control Program or the SIS commands. The switcher has two internal, hot-swappable 100 VAC to 240 VAC, 50-60 Hz, 175-watt power supplies that provide worldwide power compatibility and reliability. DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Introduction...
  • Page 11: Configurability

    Fiber boards can follow DVI boards and DVI boards can follow fiber boards within the above size rules. • If you install a blank panel, all slots under it MUST contain blank panels (you cannot skip a slot). DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Introduction...
  • Page 12: Installation

    The input numbers supported by the I/O board in slot 2 (locations 5 through 8) are as follows: A = 5, B = 6, C = 7, D = 8. DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Installation...
  • Page 13 DVI-D INPUTS DVI-D OUTPUTS DMS 44 DVI DVI-D INPUTS DVI-D OUTPUTS DMS 44 DVI DVI-D INPUTS DVI-D OUTPUTS DMS 44 DVI DVI-D INPUTS DMS 44 DVI Figure 5. DMS 3200 Features DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Installation...
  • Page 14: Making Connections

    Connect the opposite ends of these fiber optic cables to the Input connectors on DFX 100 Rx receivers. Input LEDs — These LED light amber to indicate fiber connections. These LEDs light green to indicate signal transmissions. DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Installation...
  • Page 15 Installing a Power Supply Module (DMS 1600 and DMS 3600) page 28 to replace the power supply). ¢ Fans (DMS 1600 and DMS 3600) — See Removing and Installing a Fan (DMS 1600 and DMS 3600) on page 29. DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Installation...
  • Page 16: Front Panel

    Power LED (DMS 2000 and DMS 3200) — Indicates that the power supply is operating within normal tolerances. NOTE: The power supply is fixed, and not field replaceable, on the DMS 2000 and DMS 3200. DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Installation...
  • Page 17: Front Panel Operations

    If an output button blinks, that output is muted. To toggle mute on and off, press and hold the output button for 2 seconds. Press an input button. The buttons for all tied outputs light. DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Front Panel Operations...
  • Page 18: Saving Or Recalling A Preset

    C O N T R O L 2 seconds ENTER PRESET VIEW ENTER PRESET VIEW Preset and View blink twice to indicate the mode change. Release the buttons. DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Front Panel Operations...
  • Page 19: Remote Control

    If necessary, enter the appropriate password. If the password is accepted, the switcher responds with Login User or Login Administrator . If the password is not accepted, the Password prompt reappears. DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control...
  • Page 20: Number Of Connections

    = Carriage return and line feed = Carriage return (no line feed) = Pipe (can be used interchangeably with the character) = Escape key (hex 1B) = Can be used interchangeably with the character DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control...
  • Page 21: Command And Response Table For Sis Commands

    Command and Response Table for SIS Commands Command ASCII Command Response Additional Description (Host to Unit) (Unit to Host) NOTES: • Commands can be entered back-to-back in a string, with no spaces. For example: 1*1!02*02&003*003% . • The matrix switchers support 1-, 2-, and 3-digit numeric entries ( 1*1! , 02*02& , or 003*003% ). Create ties NOTES: •...
  • Page 22 Command ASCII Command Response Additional Description (Host to Unit) (Unit to Host) EDID NOTE: In the commands below, the EDID data can come from either an active output or be set to a specified value. Assign EDID data to an input EDID EdidA = Input number...
  • Page 23 Command ASCII Command Response Additional Description (Host to Unit) (Unit to Host) (EDID) values (continued): value for DMS Resolution Resolution value for DMS model model 1600 2000 3200 3600 1600 2000 3200 3600 640x480 @ 60 Hz 1365x768 @ 75 Hz 640x480 @ 75 Hz 1366x768 @ 60 Hz 800x600 @ 60 Hz...
  • Page 24 Command ASCII Command Response Additional Description (Host to Unit) (Unit to Host) Channel mute commands Channel mute Mute output (no signal is output). Channel unmute Unmute output (signal is output). Read channel mute 1 = mute on, 0 = mute off. Global channel mute Mute all outputs.
  • Page 25 Command ASCII Command Response Additional Description (Host to Unit) (Unit to Host) Information requests X& Information request A0X0 • • In the response: X& shows the number of available inputs and outputs for this configuration. A0X0 has no meaning for this product. shows the board type installed in each slot.
  • Page 26: Command And Response Table For Ip-Specific Sis Commands

    Command and Response Table for IP-Specific SIS Commands Command ASCII Command Response Additional Description (host to unit) (unit to host) IP and serial port setup EX1! X1!] Set IP address Default: 192.168.254.254 X1!] Read IP address EX1! X1!] Set subnet mask Default: 255.255.0.0 Read subnet mask X1!]...
  • Page 27: Installing And Starting The Control Program

    Click the M filtering letter ( ) to jump to the page of downloads nearest the program. Click Download for the Matrix Switchers Control Program ( 4 4 4 4 4 4 4 4 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control...
  • Page 28: First-Time Connection Considerations

    If you have not installed the latest Matrix Switchers Control Program, click Cancel and install the program. Reconnect the Installing the switcher to the PC via the Configuration port (see Program on page 19). DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control...
  • Page 29: Starting The Program

    For a comm port, check the baud rate displayed in the Comm Port Selection window. If you need to change the baud rate, click the Baud button and double-click the desired baud rate. DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control...
  • Page 30 In the event of a complete system reset, the passwords convert to the default, which is no password. Click Connect . The Matrix Switchers Control Program is ready for operation. DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control...
  • Page 31: Accessing The Html Pages

    You must ping the DMS matrix switcher as shown in step 5 for the IP address change to take place. The response should show the new IP address, as shown in the following figure. DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control...
  • Page 32: Loading The Start-Up Page

    Start the web browser program. Click in the Address field. Enter the Matrix IP address in the Address field. NOTE: 192.168.254.254 is the factory-specified default value for this field. DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control...
  • Page 33 Enter the appropriate administrator or user password in the Password field and click OK . The switcher downloads the start-up page. The switcher is ready for operation via HTML remote control. Figure 11. Downloaded Start-up Page DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control...
  • Page 34: Maintenance And Modifications

    Les décharges électrostatiques (ESD) peuvent endommager l’équipement, même si vous ne pouvez pas le sentir, le voir ou l’entendre. DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Maintenance and Modifications...
  • Page 35 Gently seat the board or panel in the backplane. Use a screwdriver to tighten the left and right knurled knobs to lock the board or panel in place. DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Maintenance and Modifications...
  • Page 36: Removing And Installing A Power Supply Module (Dms 1600 And Dms 3600)

    1 .2 /6 0 0 -2 1 .2 /6 0 0 -2 IT C Knurled Power Knobs Figure 13. Remove and Install a Power Supply Module DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Maintenance and Modifications...
  • Page 37: Removing And Installing A Fan (Dms 1600 And Dms 3600)

    ) that secure the row identification plate (identifying FAN ASSIMBLY the rows of the adjacent DVI input and output connectors) to the fan. Retain the plate. 1 1 1 1 1 1 1 1 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Maintenance and Modifications...
  • Page 38 Gently seat the fan in the backplane. Use a screwdriver to tighten the top and bottom knurled knobs to lock the fan in place. Secure the row identification plate to the fan. DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Maintenance and Modifications...
  • Page 39 In no event will Extron Electronics be liable for direct, indirect, or consequential damages resulting from any defect in this product even if Extron Electronics has been advised of such damage.
  • Page 40 Worldwide Headquarters: Extron USA West, 1025 E. Ball Road, Anaheim, CA 92805, 800.633.9876...

This manual is also suitable for:

Dms 2000Dms 3200Dms 3600

Table of Contents