Avaya Virtual Services Platform 7000 Series Installation Manual page 41

Hide thumbs Also See for Virtual Services Platform 7000 Series:
Table of Contents

Advertisement

VSP 7000 installation
LED
Amber (Blinking)
Emerald (Solid)
Emerald (Blinking)
Emerald / Amber
(Alternating)
FA1 / FA2
Ruby (Solid)
Ruby (Blinking)
Ruby (Fast Blinking)
Sapphire (Solid)
Sapphire (Blinking)
Checking status LEDs to verify switch installation
State
The power supply in slot 1/2 is
installed, but not providing power to
the switch (Non-Service Effecting).
The power supply in slot 1/2 is
operating normally.
The power supply in slot 1/2 is
disconnected from power after
operating (Non-Service Effecting).
The power supply in slot 2 is
operating, but the airflow mode does
not match the power supply in slot 1.
You must replace the power supply
to match the airflow.
If both FAN LEDs are ruby, the unit
shut down from an over voltage fault
or an over temperature fault.
For an over voltage fault, the unit
shuts down within four seconds. For
an over temperate fault, the unit
shuts down immediately.
Note:
The unit software monitors the
internal temperature and
generates log and SNMP traps to
indicate that the unit is running
above the high temperature
threshold and is approaching a
critical over temperature fault.
The fan tray in position 1/2 is
missing. You must install a fan tray,
and the fan tray must match the
airflow mode of the power supply.
The fan tray in position 1/2 is
connected but is not operating.
Replace the failed fan tray.
The fan tray in position 1/2 is front to
back airflow and is operating
normally.
The fan tray in position 1/2 is front to
back airflow and has degraded.
Check for a fan failure and replace if
necessary.
Description
July 2013
41