3. CFM
3.1 Configuration
CLI
config
ACLI
config terminal
3.1.1
CFM
3.1.1.1 Pre 7.1.1.0 for the ERS 8800 and release 3.3 for the VSP 9000
CLI - MD =spbm, B-VLANs 4051 & 4052, MA = 4051 & 4052, MEP = 2, Level = 5 (default = 4)
cfm md spbm create
cfm md spbm ma 4051 create
cfm md spbm ma 4052 create
cfm md spbm ma 4051 mep 2 create state enable
cfm md spbm ma 4052 mep 2 create state enable
vlan 4051 add-nodal-mep spbm.4051.2
vlan 4052 add-nodal-mep spbm.4052.2
vlan 4051 add-nodal-mip-level 5
vlan 4052 add-nodal-mip-level 5
ACLI - MD = spbm, B-VLANs 4051 & 4052, MA = 4051 & 4052, MEP = 2, Level =5 (default = 4)
cfm maintenance-domain spbm
cfm maintenance-association spbm 4051
cfm maintenance-association spbm 4052
cfm maintenance-endpoint spbm 4051 2 state enable
cfm maintenance-endpoint spbm 4052 2 state enable
vlan nodal-mep 4051 spbm 4051 2
vlan nodal-mip-level 4051 5
vlan nodal-mep 4052 spbm 4052 2
vlan nodal-mip-level 4052 5