Appliance Description - Viessmann VITOLIGNO 300-H Series Operating Instructions Manual

Boilers for woodchips and pellets with ecotronic weather-compensated, digital boiler and heating circuit control unit
Table of Contents

Advertisement

Intended use
(cont.)
Incorrect usage or operation of the appliance (e.g. the
appliance being operated for longer periods when
open) is prohibited and will result in an exclusion of lia-
bility. Incorrect usage also occurs if the components in
the heating system are modified from their intended
use (e.g. if the flue gas and ventilation air paths are
sealed) or if other fuels than those intended for this
appliance are used.

Appliance description

The Vitoligno 300-H is an automatic boiler suitable for
burning woodchips and pellets.
Commissioning
The commissioning and matching of the appliance to
local conditions and building characteristics, as well as
instructing the user in the operation of the system,
must be carried out by your contractor.
Recurring emissions tests
Your heating contractor must prepare the boiler for
this test.
Notify your heating contractor approx. 2 weeks prior
to the next emissions test being due.
Ensure that suitable fuel is available. See chapter
Ordering fuel.
Your system is preset
Your heating system is preset at the factory and is
therefore ready for operation following commissioning
by your contractor:
Central heating
Between 06:00 h and 22:00 h, rooms are heated to
20 °C "Set room temp" (standard room tempera-
ture).
Between 22:00 h and 06:00 h, rooms are heated
with "Set red room temp" (room temperature for
reduced heating operation, night setback).
As the user of new combustion equipment, you may be
obliged to notify your local flue gas inspector of the
installation [check local regulations]. Your local flue gas
inspector will also inform you [where appropriate]
about work that may have to be carried out on your
combustion equipment (such as regular checks, clean-
ing).
Prepare and carry out the emissions tests according to
the 1st BImSchV:
See installation and service instructions
DHW heating
Between 06:00 and 22:00 h, the DHW is heated to
60 °C "Set DHW temperature". Any installed DHW
circulation pump is switched on.
Between 22:00 and 06:00 h, the DHW cylinder is not
reheated. Any installed DHW circulation pump is
switched off.
Note
Any DHW heating begun before 22:00 h is termina-
ted.
Frost protection
Your boiler, DHW cylinder and heating water buffer
cylinder are protected against frost.
Wintertime/summertime changeover
This changeover is automatic.
Introductory information
9

Advertisement

Table of Contents
loading

Table of Contents