Checking Fault Messages - Viessmann VITOLIGNO 300-H Series Operating Instructions Manual

Boilers for woodchips and pellets with ecotronic weather-compensated, digital boiler and heating circuit control unit
Table of Contents

Advertisement

Checking information
4.
/
for "General", "Boiler", "Heating" or
|
~
"DHW".
The following overviews show the tempera-
tures displayed in the submenus.
5.
to confirm.
d
Temperatures in the "General" submenu:
Outside temperature
Set system temperature
Temperatures in the "Boiler" submenu:
Boiler water temperature
Boiler return
Flue gas temperature

Checking fault messages

If any faults have occurred in your heating system, the
" " symbol flashes on the display and "Fault" is
shown.
The heating contractor uses fault messages to quickly
pinpoint the cause of your boiler's fault. This can
reduce the time required to resolve the fault and there-
fore also your costs.
Make a note of the fault message displayed so you
can advise your heating contractor accordingly. This
makes preparations easier and may save extra travel
expenses.
Danger
Fault messages indicate faults in the heating
system. If faults are not rectified, they can have
life threatening consequences.
Do not acknowledge the fault message sev-
eral times in quick succession.
If a fault occurs, shut the system down and
make it safe.
Rectify the fault or contact your heating con-
tractor immediately.
When rectifying the fault, no-one else should
be present in the danger zone around the
heating system.
1. You can call up the cause of the fault with
Fault
Outside temp sensor
Fault O2 probe
Acknowledge with
Fig. 36
(cont.)
d
.
34
91
OK
Temperatures in the "Heating" submenu:
Set room temperature
Set reduced room temperature
Set flow temperature
Actual flow temperature
Temperature in the "DHW" submenu:
Set DHW temperature
Actual DHW temperature
Set return temperature
Actual return temperature
2. Pressing ? calls up information on the heating sys-
tem characteristics.
Tips on which measures you can take yourself
before notifying your heating contractor are also
displayed.
3. Make a note of the cause of the fault and the fault
code on the right. In the example: "Outside sen-
sor 34" and "Fault O2 probe 91".
This enables the heating contractor to be better
prepared for the service call and may save addi-
tional travelling costs.
4. If you want to acknowledge the fault message, fol-
low the instructions in the menu.
The fault message is copied to the menu.
Boiler water temp
Fault
Boiler
Buffer
Heating
Continue with
Fig. 37
Note
If you have connected an alarm to alert you to
fault messages (e.g. a buzzer), this is deactiva-
ted when the fault message is acknowledged.
If the fault can only be rectified at a later date,
the fault message is displayed again the next day
and the alarm is switched on again.
Calling up an acknowledged fault message
Press the following buttons:
1.
repeatedly until the "standard menu" is dis-
ä
played.
Checks
48°C
OK
41

Advertisement

Table of Contents
loading

Table of Contents