Superior Fireplaces TF18NR Installation And Operation Instructions Manual page 32

Unvented (vent-free) gas log heaters
Table of Contents

Advertisement

WARNING: If you smell gas
• Shut off gas supply.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow the
gas supplier's instructions.
• If you cannot reach your gas supplier, call the fi re department.
IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint,
paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes
may mix with combustion air and create odors. These odors will disappear over time.
OBSERVED PROBLEM
Appliance produces unwanted
odors
Appliance shuts off in use (ODS
operates)
Gas odor even when control knob
is in OFF position
Gas odor during combustion
Log set cycles to pilot, but room
temperature drops to a lower
than ideal level before log set
comes back on
32
TROUBLESHOOTING
Continued
POSSIBLE CAUSE
1. Appliance burning vapors from
paint, hair spray, glues, cleaners,
chemicals, new carpet, etc. (See
IMPORTANT statement above)
2. Low fuel supply (propane/LP
only)
3. Gas leak. See Warning state-
ment at top of Page
1. Not enough fresh air is avail-
able
2. Low line pressure
3. ODS/pilot is partially clogged
1. Gas leak. See Warning state-
ment at top of Page
2. Control valve or gas control
defective
1. Foreign matter between con-
trol valve and burner
2. Gas leak. See Warning state-
ment at top of Page
1. Hand-held remote control is
too close to appliance
SuperiorFireplaces.us.com
REMEDY
1. Open window to ventilate
room. Stop using odor caus-
ing products while appliance
is running
2. Refi ll supply tank (propane/
LP only)
3. Locate and correct all leaks
(see Checking Gas Connec-
tions, Page 15)
1. Open window and/or door for
ventilation
2. Contact local natural or pro-
pane/LP gas company
3. Clean ODS/pilot (see Cleaning
and Maintenance, Page 28)
1. Locate and correct all leaks
(see Checking Gas Connec-
tions, Page 15)
2. Replace control valve or gas
control
1. Take apart gas tubing and
remove foreign matter
2. Locate and correct all leaks
(see Checking Gas Connec-
tions, Page 15)
1. Move hand-held remote con-
trol unit farther away from the
appliance