INSTALLING DAMPER CLAMP ACCESSORY
(REQUIRED FOR VENTED APPLICATIONS)
NOTE: When used as a vented appliance, it must be
installed only in a solid-fuel-burning fi replace with
a working fl ue and constructed of noncombustible
material.
For Massachusetts Residents Only: Installation
of this gas log set as a vented appliance in the
Commonwealth of Massachusetts requires the
damper be permanently removed or welded in the
fully open position.
If your appliance is a manually-controlled model,
you may use this appliance as a vented product.
There are three reasons for operating your appli-
ance in the vented mode.
1. The fi replace does not meet the clearance to
combustibles requirements for vent-free opera-
tion.
2. State or local codes do not permit vent-free
operation.
3. You prefer vented operation.
If reasons number 1 or 2 above apply to you, you
must permanently open chimney fl ue damper. You
must install the damper clamp accessory (to order,
see Accessories, Pages 34-35). This will ensure
vented operation (see Figure 10). The damper
clamp will keep damper open. Installation instruc-
tions are included with clamp accessory.
See chart below for minimum permanent flue
opening you must provide. Attach damper clamp
so the minimum permanent fl ue opening will be
maintained at all times.
Area of Various Standard Round Flues
Diameter
5"
6"
7"
8"
Chimney
Minimum Permanent
Height
6' to 15'
15' to 30'
12
INSTALLATION
Continued
Masonry Fireplace
INSTALLING APPLIANCE BASE ASSEMBLY
heater to fi replace fl oor. If not, heater
will move when you adjust controls.
Moving heater may cause a gas leak or
log misplacement.
fi replace, special care is needed. You
must raise the fi replace fl oor to allow
access to heater control panel. This
will ensure adequate air fl ow and guard
against sooting and controls being
damaged. Raise fi replace fl oor with
noncombustible material. Make sure
Area
material is secure.
20 sq. inches
29 sq. inches
39 sq. inches
51 sq. inches
base assembly by burners. This could
damage heater. Only handle base as-
sembly by grates.
Flue Opening
39 sq. inches
IMPORTANT: Make sure the heater burners are
29 sq. inches
level. If appliance is not level, appliance will not
work properly.
SuperiorFireplaces.us.com
Damper
Clamp
Damper
Damper
Clamp
Damper
Manufactured Fireplace
Figure 10 - Attaching Damper Clamp
WARNING: You must secure this
WARNING: If installing in a sunken
CAUTION: Do not pick up heater
Damper
126816-01F

Hide quick links: