Equipment Shutoff Valve
Gas Meter
Figure 17 - Checking Gas Joints (Natural Gas
Only)
PRESSURE TESTING APPLIANCE GAS
CONNECTIONS
1. Open equipment shutoff valve (see Figure 15,
Page 15).
2. Open main gas valve located on or near gas
meter for natural gas or open propane/LP
supply tank valve.
3. Make sure control knob of appliance is in the
OFF position.
4. Check all joints from gas meter to equipment
shutoff valve for natural gas or propane/LP
supply to equipment shutoff valve for propane/
LP (see Figure 16, Page 15 or Figure 17). Apply
noncorrosive leak detection fl uid to all joints.
Bubbles forming show a leak.
5. Correct all leaks at once.
6. Light appliance (see Operation, Page 25).
Check all other internal joints for leaks.
7. Turn off appliance (see To Turn Off Gas to Ap-
pliance, Page 26.
INSTALLING SWITCH
The AUTO/OFF/ON switch for this log set is installed
into the small single log accompanying this log set.
This switch needs to be used only if remote or wall
switch is not being used.
Connect the wires to the valve from the switch
assembly as shown in Figure 18.
Control Valve
Figure 18 - Connecting Wires
16
INSTALLATION
Continued
INSTALLING OPTIONAL REMOTE
(ACCESSORY)
Installing Remote Receiver
Remote control accessories are available separately
(see Accessories, Pages 34-35). Read instructions
shipped with remote control along with instructions
below before attempting installation.
1. If unit is already installed in fi replace, continue
Control Valve
Location
let cool before handling any part of
appliance. Make sure gas is turned
of to unit.
2. Carefully remove logs and set aside.
3. Locate mounting screws on sides of appliance
4. Disconnect gas line from appliance base as
son must connect and disconnect gas
to appliance. Follow all local codes.
5. Remove appliance base from fi replace.
6. If installed, disconnect AUTO/OFF/ON switch wire
7. Connect wires from hardware pack (with remote
8. If appliance was removed from fi replace before
To OFF
9. If logs were removed from appliance for install
Terminal on
Switch
10. Place remote receiver on fi replace fl oor next to
To AUTO
Terminal on
Switch
SuperiorFireplaces.us.com
with these instructions. If unit has not been
installed in fi replace, go to step 6 and continue
installation of remote accessory.
WARNING: Turn off appliance and
base assembly and remove screws. Set screws
aside for reinstallation.
shown in Figure 11, Page 13.
WARNING: A qualifi ed service per-
from control valve at TPTH and TH locations (see
Figure 19, Page 17).
receiver bracket) to control valve at the TPTH
and TH locations as shown in Figure 19, Page
17. Connect other ends of these wires to remote
receiver wires.
NOTE: Make sure excess wire does not interfere
with burner or pilot.
installation of remote accessory, see Installing
Appliance Base Assembly on Page 12 to reinstall
appliance into fi replace. Test gas connection for
leaks (see Checking Gas Connections, Page 15).
remote accessory, replace logs (see Installing
Logs, Embers and Volcanic Stone, Pages 17-
24).
control valve. Make sure the remote receiver and
wires are not on or touching either gas burner