5. Wait fi ve (5) minutes to clear out any gas.
Then smell for gas, including near the fl oor. If
you smell gas, STOP! Follow "B" in the safety
information, column 1. If you don't smell gas,
go to the next step.
6. Press in and turn control knob counterclock-
wise
to the PILOT position. Press in
control knob for fi ve (5) seconds (see Figure
53, Page 27).
NOTE: You may be running this appliance for
the fi rst time after hooking up to gas supply. If
so, the control knob may need to be pressed
in for 30 seconds or more. This will allow air
to bleed from the gas system.
7. With control knob pressed in, press and release
Igniter button on left side of log set. This will
light pilot. The pilot is attached to the front
of U-shaped burner. If needed, keep pressing
Igniter button until pilot lights.
NOTE: If pilot does not stay lit, contact a quali-
fi ed service person or gas supplier for repairs.
Until repairs are made, light pilot with match.
To light pilot with match, see Manual Lighting
Procedure.
8. Keep control knob pressed in for 30 seconds
after lighting pilot. After 30 seconds, release
control knob.
• If control knob does not pop out when re-
leased, contact a qualifi ed service person or
gas supplier for repairs.
NOTE: If pilot goes out, repeat steps 4
through 8.
9. Slightly push in and turn control knob counter-
clockwise
to the ON position. If using
a hand-held remote control accessory, go to
Optional Hand-Held Remote Operation on Page
27.
10. Wait one minute and put switch in ON position
to light burners.
NOTE: AUTO is only functional when using
GWMS2 optional accessory. If hand-held
remote control is installed but not being used,
slide remote selector switch to ON (It must
be in this position for burners to light. Switch
will be in REMOTE position if using hand-held
remote).
11. Set fl ame adjustment knob to any level between
HI and LO.
26
OPERATION
Continued
12. To leave pilot lit an shut off burners only: turn
control knob clockwise
position, or use remote control manual OFF but-
ton , or set selector switch in the OFF position.
CAUTION: Do not try to adjust
heating levels by using the equipment
shutoff valve.
WARNING: Make sure the remote
selector switch is in the OFF position
when you are away from home for long
periods of time. Appliance will come
on automatically with selector switch
in the ON position.
Pilot Burner
Figure 52 - Pilot (Natural)
1. Turn control knob clockwise
position.
2a. Set switch in the OFF position.
2b. If Using Optional Hand-Held Remote: Set
selector switch in the OFF position to prevent
draining battery.
3. Close equipment shutoff valve (see Figure 15,
Page 15).
1. Follow steps 1 through 6 under Lighting In-
structions, Page 25.
2. Press control knob and light pilot with match.
3. Keep control knob pressed in for 30 seconds
after lighting pilot. After 30 seconds, release
control knob. Now follow steps 9 through 11,
Lighting Instructions, Page 25.
SuperiorFireplaces.us.com
to the PILOT
Igniter
Electrode
TO TURN OFF GAS
TO APPLIANCE
MANUAL LIGHTING
PROCEDURE
126816-01F