Appendix A - Specifications - ADC H4TU-C-319 List 1 Line Unit User Manual

Central office (co) side of a t1 transmission system
Hide thumbs Also See for H4TU-C-319 List 1 Line Unit:
Table of Contents

Advertisement

Appendix A - Specifications

A
PPENDIX
Power
Line Voltage
CO Supply
Electrical Protection
Fusing
Environmental
Operating Temperature
Operating Humidity
Physical
Height
Width
Depth
Weight
Mounting
HDSL4
Line Code
Transmission
CSA Reach
Media
Output
Line Impedance
Maximum Insertion Loss
Maximum Loop Attenuation
Start-Up Time
DSX-1
Line Impedance
Line Rate
Line Format
Frame Format
Pulse Output
Input Level
58
A - S
PECIFICATIONS
0, -185 Vdc, ±123 Vdc (Voltage is applied across Loop 1 and Loop 2.)
-48 Vdc nominal (-42.5 Vdc to -56.5 Vdc)
See
"Power Consumption"
Current Drain" on page
Secondary surge and power cross-protection on HDSL4 ports. Requires external
primary protection.
Internal; connected to fuse alarm output on pin 10
-40°F to +149°F (-40°C to +65°C)
5% to 95% (non-condensing)
4.750 in. (12.10 cm)
0.625 in. (1.59 cm)
10 in. (25.4 cm)
0.5 lb. (0.23 kg)
3192 high-density mechanics shelf
784 kbps Overlapped Pulse Amplitude Modulation (OPAM) transmission per pair per
HDSL4 standard in ANSI T1.418 Issue 2
Full duplex
34 kft. maximum using 26 AWG wire: 12kft. (span 1), 11 kft. (span 2), 11 kft. (span 3)
One non-loaded, copper, four-wire cable pair
+14.1 dBm ±0.5 dBm at 135Ω
135Ω
Span 1 = 47 dB at 196 kHz
Span 2 and Span 3 = 43 dB at 196 kHz
Span 1 = 31 dB
Span 2 and Span 3 = 29 dB
30 sec. (typical), 1 min. (maximum)
100Ω
1.544 Mbps ±200 bps
Alternate Mark Inversion (AMI) or Bipolar with 8-Zero Substitution (B8ZS)
Extended SuperFrame (ESF), SuperFrame (SF), or Unframed (UNFR)
pk-pk
6 V
pre-equalized for 0 to 655 feet of ABAM cable
+1.5 to -7.5 dB DSX
September 12, 2003
and
"Maximum Power Dissipation"
61.
LTPH-UM-1031-03, Issue 3
and
"Maximum
H4TU-C-319 List 1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hdsl4H4tu-c-319-l1