Testing With H4Tu-R Bert Generator - ADC H4TU-C-319 List 1 Line Unit User Manual

Central office (co) side of a t1 transmission system
Hide thumbs Also See for H4TU-C-319 List 1 Line Unit:
Table of Contents

Advertisement

LTPH-UM-1031-03, Issue 3
T
H4TU-R BERT G
ESTING WITH
The H4TU-R BERT Generator screen allows transmission of an unframed test signal from the H4TU-R towards
either the network (NET) or customer (CPE). Bit error rates are calculated and display on the Monitor screen.
1
Press
R
to logon remotely, then press
2
Use the
and
3
Use the arrow keys to select an option, then press the
Table 19 on page 56
ENTER
4
Press
to activate your choice.
5
To view BERT status, press
ENTER
.
6
Press
R
to return to the H4TU-C logon screen. You can exit the status screen while signal generation is active.
Monitor
Performance
Use <Spacebar> to cycle through option settings and <Enter> to activate
ID: xxxx—-xxxx—-xxxx--xxxx
The test pattern is sent out either from the line unit towards the network (toward NET) or from
the remote unit towards the customer (toward CPE). Both test payloads must be looped back so
they can be returned to the unit for BER detection. BER detection is performed in the line unit
for both switch settings.
Tests done towards the NET must be looped at some point external to the higher circuit. Tests
done towards the CPE can either be looped back at some external point beyond the remote unit,
or they can be looped back internally by a higher loopback, such as NREM. The test payload,
for the CPE direction, also passes back and forth over the HDSL4 link to the H4TU-C before it is
analyzed for errors.
H4TU-C-319 List 1
C
to select the Config menu
arrow keys to select BERT Generator, then press
for a list of BERT Generator option settings.
twice, then, using the
ESC
Event Log
Config
+----------------------+
| Standard Options ->
| ADC Options
|
BERT Generator
+--------------------------------------+
| BERT Signal Generator
| BERT Signal Pattern
| BERT Signal Linecode
| BERT Signal Direction
| BERT Interval
+--------------------------------------+
02/01/2002 12:30:01
Figure 31. H4TU-R BERT Generator Screen
September 12, 2003
ENERATOR
(Figure
ENTER
SPACEBAR
to cycle through the settings. Refer to
arrow key to select the Monitor menu, press
Inventory
Report
|
->
|
->
|
:
: 1 in 8
: AMI
: NET only
: Continuous
H4TU-R
31).
.
Rlogon
Help
ENA
|
|
|
|
|
System:
OK___
Testing
57

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hdsl4H4tu-c-319-l1

Table of Contents