H4Tu-C-319 List; Overview; Features - ADC H4TU-C-319 List 1 Line Unit User Manual

Central office (co) side of a t1 transmission system
Hide thumbs Also See for H4TU-C-319 List 1 Line Unit:
Table of Contents

Advertisement

LTPH-UM-1031-03, Issue 3
O
VERVIEW
The H4TU-C-319 List 1 is the Central Office (CO) side of a T1 transmission system. The ADC
product family (hereafter referred to as "HDSL4") is based on the HDSL4 standard ANSI T1.418 Issue 2.
The H4TU-C, when used with an H4TU-R remote unit, transmits a 1.544 Mbps payload up to a maximum distance
of 12 kft. over two unconditioned copper pairs. Using two doublers (H4Ds), the Carrier Service Area (CSA) reach
can be extended to a maximum of 34 kft. The H4TU-C-319 List 1 is designed to mount in 3192 mechanics shelves.
For a list of compatible shelves see
The H4TU-C-319 List 1 complies with the protection switching features of the PSC-606 List 1
protection switching card. See the PSC-606 List 1 technical practice, document number
LTPH-TP-1006-xx for detailed information.
F
EATURES
Standard features include:
HDSL4 transmission features
Lightning and power cross-protection on HDSL4 interfaces
Full-duplex HDSL4 transmission on four wire at 1.568 Mbps
Ultra-low wander (Stratum 1 compliant)
Grounded loop detection on either HDSL4 spans
Spectrum compatibility with Asymmetric Digital Subscriber Line (ADSL) services
Bit Error Rate Tester (BERT)
Three-span range with two doublers (34 kft, 26 AWG)
Front-panel provisioning features
Four-character status display
DS1 splitting and bridging access
Status Light Emitting Diode (LED)
RS-232 craft port for connection to a maintenance terminal
MODE and SEL pushbuttons
Front-panel dual loopback commands
Maintenance screens for inventory, provisioning, and troubleshooting
DS1 and HDSL4 performance monitoring
DS1 and HDSL4 alarm histories
Payload (PL) and HDSL Generic (HG) loopback source identification
Margin Alarm (MAL) threshold
Report menu option for downloading status and performance monitoring data to a file
Sources sealing current when connected to any locally powered H4TU-R-402
Remote access and control of H4TU-R test signal generator

H4TU-C-319 List 1

"Appendix C - Compatibility" on page
September 12, 2003
®
four-wire HDSL2
65.

Overview