Generic Loopback Commands

The HDSL4 Generic Loopback (GNLB) commands allow you to use inband codes to loop up either
NLOC (4-in-7) or NREM (3-in-7) towards the network. In addition, these inband codes loop up CREM (6-in-7)
or CLOC (5-in-7) towards the customer. Either loopup condition can be terminated (looped down) with the 3-in-5,
SMJK loopdown code. All inband codes must be present for at least 5 seconds before the HDSL4 system responds.
TLOS is a logic loopback caused by loss of the DS1 input from the CI.
Figure 29 on page 50
generic loopback commands. See
HDSL4 systems feature the SmartJack option, which can emulate a Network Interface Device
(NID) for the purpose of loopback testing of the HDSL4 circuit. SMJK and NREM loopbacks
perform the same functions but their initiation differs. SMJK indicates that the loopback was
initiated by the 2-in-5 inband command. NREM, on the other hand, is initiated by the 3-in-7
inband command or by a command issued from the maintenance terminal or the MODE and SEL
pushbuttons.
Use the inband commands to enable or disable the SMJK loopback options. The H4TU-C-319
system setting is normally enabled to recognize all inband SmartJack loopback commands.

Special Loopback Commands

A3LB and A5LB loopback commands can be sent by a test set connected to the H4TU-C or H4TU-R. See
Table 17 on page 52
and
A3LB and A5LB are special, addressable, repeater loopback modes which are supported by the H4TU-C. These
loopback modes provide the HDSL4 system with sophisticated maintenance and troubleshooting tools. A3LB and
A5LB are patterned after the Westell addressable T1 repeater loopbacks.
The A5LB loopback selection complies with that proposed for HDSL4 systems in the T1E1.4/92 looopback
recommendation with the following additions:
Query loopback
IOR (Intelligent Office Repeater) power-down
Four loopback time-out choices
Initiation from either end
Repeating bit error signatures
Alternate query loopback
A5LB does not block the arming code from exiting the H4TU-C-319 into the network. Since A5LB never blocks
the arming code from exiting the H4TU-C, the Far-End Activate code is not available in A5LB. A3LB supports
the additional (1-in-6) SMJK loopback command.
H4TU-C-319 List 1
summarizes the available loopbacks in the system, and
"GNLB Test Procedures" on page 51
Table 18 on page 53
for a list of the commands.
September 12, 2003
Table 16
summarizes the HDSL4
for the test procedures that apply
Testing
47