Cornelius NITROPRO MINI Installation And Operator's Manual page 32

Hide thumbs Also See for NITROPRO MINI:
Table of Contents

Advertisement

Nitropro Mini Installation Manual
Step
REDUCED FOAM HIGHT adjustment:
A. Pull out regulator control knob to unlock for
adjustments.
B. Adjust the regulator control knob slightly
(approximately 1/8th of a turn) to the LEFT
(counter-clockwise). Only very fine adjustments
are required. This reduces the amount of
Nitrogen injected.
C. Push regulator control knob in to lock set
3
pressure.
D. Open the RIGHT Tap Handle and dispense about
8 oz. of product to drain the line of product at the
previous foam setting. Then dispense 12 oz. of
product and confirm the foam head height.
Repeat and dispense another 12 oz. to confirm
setting.
E. Repeat step A if a further reduction of foam head
height is required.
INCREASED FOAM HIGHT adjustment:
A. Pull out regulator control knob to unlock for
adjustments.
B. Adjust the regulator control knob slightly
(approximately 1/8th of a turn) to the RIGHT
(clockwise). Only very fine adjustments are
required. This increases the amount of Nitrogen
injected
C. Push regulator control knob in to lock set
4
pressure
D. Open the RIGHT Tap Handle and dispense about
8 oz. of product to drain the line of product at the
previous foam setting. Then dispense 12 oz. of
product and confirm the foam head height.
Repeat and dispense another 12 oz. to confirm
setting.
E. Repeat step A if a further increase of foam head
height is required
Reinstall the regulator access cover.
5
Publication Number: 548000106INS
Action
- 28 -
Figure 44
Figure 45
Figure 46
© 2018, Cornelius Inc.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nitropro mini

Table of Contents