Backing Up Data At Sinamics S120; Data Backup On The Compact Flash Card - Siemens SINAMICS S120 Faq

About drive technology
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

SINAMICS S120 at Technology CPU Entry ID: 21767896
4.3

Backing up data at SINAMICS S120

There are two options for backing up the data of SINAMICS S120:
Storing the data on the compact flash card of the control unit
Uploading the data to a STEP 7 project and storing the data with this
project.
4.3.1

Data backup on the compact flash card

Via the parameter p977, a data backup of the parameters and BICO
interconnections can be initiated on the compact flash card.
Selecting the parameter files for data backup
The parameter files 10, 11 and 12 on the compact flash card are available
to the customer.
The following applies:
P977 = 10 : Data backup in parameter file 10
P977 = 11 : Data backup in parameter file 11
P977 = 12 : Data backup in parameter file 12
Backing up the data
To back up the data, proceed as follows:
Table 4-1 Backing up the drive data on the compact flash card
No.
1.
V1.0
Instruction
Edition 10/28/05
Requirements
Data Backup of SINAMICS S120
Note
In the Project menu, establish the
online connection to SINAMICS
S120 by selecting the menu item
Connect to target system.
25/58