C200Hx/Hg/He Features - Omron C200HX Operation Manual

Hide thumbs Also See for C200HX:
Table of Contents

Advertisement

C200HX/HG/HE Features

Name
PID Control Unit Operation Manual
Cam Positioner Unit Operation Manual
1-8
C200HX/HG/HE Features
1-8-1 C200HS and C200HX/HG/HE Capabilities
Function
Memory
User memory (UM)
Normal DM
Fixed DM
Expansion DM
Extended Data Memory
(EM)
I/O allocation
Expansion Racks
Group-2 Multipoint I/O
Units
Special I/O Units
Execution time
Basic instructions (LD)
MOV(21)
ADD(30)
Other instructions
Common processes
(END(01) processing)
I/O refresh time
Cat. No.
W241
W224
The C200HX/HG/HE CPU Units have a number of new features, but C200H and
C200HS programs can be used in the new CPU Units.
The following table shows the new capabilities of the C200HX/HG/HE PCs and
compares them with those of the C200HS.
C200HX/HG/HE
C200HE-CPU11-E: 3.2K words
C200HE-CPUj2-E: 7.2K words
C200HG-CPUj3-E: 15.2K words
C200HX-CPUj4-E: 31.2K words
6,144 words (DM 0000 to DM 6143)
(The C200HE-CPU11-E doesn't have
DM 4096 to DM 5999.)
512 words (DM 6144 to DM 6655)
0 to 3,000 words (DM 7000 to DM 9999)
6,144 words (EM 0000 to EM 6143)
C200HE: None
C200HG: 6,144 words × 1 bank
C200HX: 6,144 words × 3 banks
3 Racks
(2 Racks in the C200HE-CPUjj-E or
C200HX/HG-CPU3j-E/4j-E)
Unit numbers 0 to 9, A to F
(Incompatible with the C200HE-CPU11-E.)
(Unit numbers 0 to 9 with the
C200HE-CPUj2-E,
C200HX/HG-CPU3j-E/4j-E.)
Unit numbers 0 to 9, A to F
(Unit numbers 0 to 9 with the
C200HE-CPUjj-E or
C200HX/HG-CPU3j-E/4j-E.)
0.104 μs (C200HX)
0.156 μs (C200HG)
0.313 μs (C200HE)
0.417 μs (C200HX)
0.625 μs (C200HG)
1.250 μs (C200HE)
16.65 μs (C200HX/HG)
31.45 μs (C200HE)
C200HX/HG:
C200HE:
0.7 ms (C200HX/HG)
2.1 ms (C200HE)
Same as the C200HS, although part of
Special I/O refreshing takes 1/2 to 2/3 the
C200HS time.
Contents
Information on PID Control Unit
Information on Cam Positioner Unit
Capability
1/3 to 2/3 of C200HS time
3/4 to 4/5 of C200HS time
Section 1-8
C200HS
15.2K words
6,144 words
(DM 0000 to DM 6143)
512 words
(DM 6144 to DM 6655)
0 to 3,000 words
(DM 7000 to DM 9999)
None
2 Racks
Unit numbers 0 to 9
Unit numbers 0 to 9
0.375 μs
19.00 μs
40.10 μs
---
0.7 ms
---
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

C200hgC200he