Action One: Prior to operating your USSC 6041 Multi-Fuel Stove Ensure all doors, lids, and
cleanouts are properly closed, and then turn on.
Action Two: Refer to table below for various command inputs for the stove. Press the on button
and set initial pellet rate, for startup you will select 2.
Action Three: Monitor the burn chamber until pellets ignite. Figure 22 shows a good start up
flame. Scenarios to watch for include; too many pellets in burn pot, which constricts airflow;
pellet feed rate too fast, which will knock out the flame; or draft fan set too high, which will blow
flame out. A best practice for starting up the stove is to set pellet feed rate at 2, and setting draft
fan at seven, while using damper to fine-tune the amount of air. Occasionally, press the auger
delay the stop feed of pellets for one minute. This keeps the burn pan from filling too quick and
will help prevent pellets from knocking the flame out.
Figure 22
Turn Stove On
A: Pellet Feed Rate
B: Room Fan
C: Draft Fan
D: Agitator Control
E: On
F: Off
G: Auger Delay
H: Set Mode