General-Purpose Input Function Parameters; Parameter Setting; Displayed Items - Mitsubishi Electric MELSEC iQ-F Series User Manual

Positioning control
Hide thumbs Also See for MELSEC iQ-F Series:
Table of Contents

Advertisement

General-purpose input function parameters

This section explains the general-purpose input parameters.
Set the input response time parameters in GX Works3.

Parameter setting

This section explains how to set the input response time parameters.
Set the input response time.
Navigation window  [Parameter]  [FX5UCPU]  [Module Parameter]  [Input Response Time]
Window

Displayed items

Item
Response Type
X0 to X377
Parameters are enabled when the CPU module is powered ON or after a reset.
19 BUILT-IN I/O FUNCTION
192
19.6 General-purpose Input Functions
Description
Select the input response time between 1 point unit and 8
point unit.
High-Speed: Unit of 1 point
Normal: Unit of 8 points
Set the input response time.
Setting range
• High-Speed
• Normal
• No Setting
• 10micro-s (s)
• 50micro-s (s)
• 0.1ms
• 0.4ms
• 0.6ms
• 1ms
• 5ms
• 10ms
• 20ms
• 70ms
Default
10ms