Mitsubishi Electric MELSEC iQ-F Series User Manual page 13

Positioning control
Hide thumbs Also See for MELSEC iQ-F Series:
Table of Contents

Advertisement

Item
Response time
FX5U-MT,
FX5UC-32MT
FX5U-MT
FX5UC-MT
Circuit insulation
Indication of output motion
*1 When two COM (or +V) terminals are connected outside the CPU module, the total load current (16 output point) is 1.6 A or less.
Where  indicates: 0 or 1
To use the positioning instruction, adjust the load current of the NPN open collector output to 10 to 100 mA (5 to 24 V DC).
Item
Operation voltage range
Operation current range
Output frequency
Sink internal output circuit
■FX5U CPU module
FX5U CPU module
COM1
COM2
*1 To ground the unit, refer to the servo amplifier (drive unit) manual.
If the grounding method is not specified, carry out class-D grounding.
■FX5UC CPU module
FX5UC CPU module
COM0
*1 To ground the unit, refer to the servo amplifier (drive unit) manual.
If the grounding method is not specified, carry out class-D grounding.
Specifications
2.5 s or less at 10 mA or more (5 to 24 V DC)
Y0 to Y3
Y4 or more
0.2 ms or less at 200 mA (24 V DC)
0.2 ms or less at 100 mA (24 V DC)
Photo-coupler insulation
LED on panel turns on when output (DISP switch OUT side)
Y0
Y4
Y0
Y4
Description
5 to 24 V DC
10 to 100 mA
200 Kpps or less
Pulse train signal
Direction signal
*1
Grounding
5 to 24V DC
Pulse train signal
Direction signal
*1
Grounding
5 to 24V DC
Servo amplifier
(Drive unit)
Servo amplifier
(Drive unit)
2 SPECIFICATIONS
17
2.3 Output Specifications