Various Control Mechanisms; Fixing Temperature Control; Protective Functions - Canon MF4500 Series Service Manual

Table of Contents

Advertisement

2
Technical Overview > Fixing System > Various Control Mechanisms > Protective Functions

Various Control Mechanisms

■ Fixing Temperature Control

● Heater Temperature Control
The heater temperature control is to keep the fixing heater in the fixing film unit to the
specified temperature.
The engine controller monitors the fixing heater temperature detection signal (FSRTH) and
outputs the fixing heater drive signal (FSRD) according to the detected temperature.
The fixing heater drive PCB controls the fixing heater according to this signal to keep the
fixing heater temperature within the target values.
Engine controller
Low-voltage
power supply
CPU
Frequency
FREQSNS
detection
circuit
(220-240V model only)
FSRD
24VOFF
FSRTH
Fixing heater (H1)
Thermistor (TH1)
Pressure
roller
Fixing film
Thermal fuse (TP1)
2
Technical Overview > Fixing System > Various Control Mechanisms > Protective Functions
Fixing control
Relay drive
FU101
circuit
RL101
Fixing heater
safety circuit
Fixing heater
drive circuit
There are 11 types of target fixing temperature depending on the fixing mode.
These types are according to the paper type settings and resolution settings on a driver.
The number of sheets Normal Heavy1 Heavy2 Light OHT Envelope Envelope2 Quiet
1
2 to 6
7 to 26
27 to 41
42 to 76
77 to 150
151 to 197
More than 198
The number of sheets Post
+24V
1
2 to 6
7 to 26
27 to 41
42 to 76
77 to 150
151 to 197
More than 198

■ Protective Functions

● Protective Function of fixing assembly
Host machine carries the following 3 functions to prevent the fixing heater from overheating.
1) Protective function by CPU
CPU of engine controller monitors the thermistor (TH1) temperature consistently.
When TH1 reaches approx 220 deg C, CPU determines that the fixing heater is overheating
and stops the fixing heater drive signal (FSRD) output and also turns OFF relays to shut
the power supply to fixing heater.
2) Protection function by fixing heater safety circuit
F-2-31
Fixing heater safety circuit monitors the thermistor (TH1) temperature consistently.
When TH1 reaches approx 235 deg C, it determines that the fixing heater is overheating
and the fixing heater safety circuit turns OFF the relay drive circuit to shut the power supply
fixing mode
185
175
185
160
165
165
185
175
185
160
165
165
185
175
185
160
165
165
185
175
185
160
165
165
185
173
185
160
165
165
183
170
185
160
165
165
180
170
185
160
165
165
180
170
185
160
165
165
fixing mode
Nomal
Nomal
N/N
(Copy)
185
185
190
185
185
190
185
185
190
185
185
190
185
185
190
185
183
188
185
180
185
185
180
185
2-23
145
150
143
150
140
150
140
150
138
148
135
145
135
145
135
145
T-2-6
T-2-7
2-23

Hide quick links: