S82
Password Blocking Time
Range
0 ... 255 minutes
Default
3 (minutes)
The blocking time is set in register 82. After three incorrect password entries the modem
allows no further password request until the blocking time has elapsed. (0 = function
deactivated).
Changes are only possible in password configuration mode (see ATP).
S83
Incorrect password entries
Range
1 Byte
Default
0
All incorrect password entries are counted in register 83. The value is only stored in the
RAM, i.e. the counter in register 83 is back at 0 (zero) after an auxiliary power failure.
S99
Time Distance Between Rings
Range
10 ... 255
Default
4 (seconds)
In register S99, you can set the maximum permissible time interval between two
received rings. The default value of 7.5 seconds is OK in most cases.
S100 IP Address
Range
xxx.xxx.xxx.xxx
Default
10.10.5.1
In register S100, you can set your own IP address. The factory-set value of 10.10.5.1
must be adjusted to your network
Bear in mind, when modifying this value, that it cannot be chosen freely, but depends on
the network address of the TCP/IP network. The address is entered in the familiar
syntax (e.g. 192.168.31.5).
S101 Default Gateway
Range
xxx.xxx.xxx.xxx
Default
0.0.0.0
In register S101, you can set the default gateway. Here you enter the gateway IP
address, if connections to other subnetworks are to be established.
C53000-G1176-C175-3
Page 62 of 79