Vga Yuv Calibration - Ricoh Sargas-PJ1 Field Service Manual

Machine codes: y095/y096/y097/y098
Table of Contents

Advertisement

7.
Check the calibration result (red frame).
8.
Compare the results with the default values.
Default Values: R:802, G:802, B:802
If the result are the same as the default values, the calibration has failed.
When the calibration failed, check the video source and redo the ADC calibration.

VGA YUV Calibration

Environment
• Test equipment: Video generator
• Test signal: 720p 60Hz
• Test pattern: SMTE pattern
• Input the signal from the VGA IN port
1.
Get into the service mode.
(page 78 "How to enter the Service
Calibration
Mode")
93